Standard Models

Avtron inductive/reactive load banks (KVAR) are typically used in combination with resistive load banks (KW) to test a generator or power source at 0.8 power factor (lagging). The reactive load bank should be sized at 75% of the resistive load bank KW rating to achieve a 0.8 power factor. The resistive and reactive load banks are connected and operated in parallel.

Skid Mounted Resistive/Reactive Load Banks

^ Back to Top

Standard Models

  • LPS (1500-2000KW; 1125-1500KVAR)
The Avtron LPS Load Bank System provides an economical and convenient means for high capacity resistive and reactive load testing of AC power systems. Many specifications and local codes demand that such testing be performed at less than unity power factor, typically 0.8 p.f. To achieve a 0.8 power factor, the LPS combines resistive load (KW) with reactive load (KVAR). This combination provides a true test of the actual generator or UPS nameplate rating (KVA) and simulates a "real world" load. The Avtron LPS System is integrated on a rugged structural skid with provisions for overhead, four point lifting.

Container Resistive/Reactive Load Banks

^ Back to Top

Standard Models

  • LCV (3000/4000/5000 KW; 2250/3000/3750 KVAR)

The load bank consists of a rugged ISO style 20 foot container housing the resistive and reactive components, blowers, associated controls and interconnections. The unit has a load capacity ratings of 3750-6250 KVA at 480 VAC, 3 phase, 60 Hz. (Other voltages and frequencies are available - consult factory.) The unit is PLC controlled with a convenient hand-held remote controller. Laptop computer control with data logging is also available as an option.


Reactive Load Bank Model: K841B

K841B Load Bank
* K841B Sales Bulletin 
* K841B Drawing Sets
   
Models such as the K841 and K841B range from 50 - 1500 KVAR. They are designed for indoor or outdoor permanent installations and come complete with remote operator control panels (19" rack mount or NEMA enclosed).

Avtron inductive/reactive load banks feature non-saturating single phase and three phase iron core load reactors.

Capacity Minimum Load
Step Resolution
Load Voltage Blower Voltage Size Weight
(lbs.)
375-1875 KVAR 3.75 KVAR 480VAC; 3phase; 240/480VAC; 3phase; 600VAC; 3phase 120VAC; 3/4HP 116"L, 66"W, 80"H 7,000 to
10,000

^ Back to Top

Note: Other models with different KVAR and Voltage ratings are available on special order. 
Control Power:
Typical power required for control circuit operation is 120VAC, 1phase, 60 Hz. If 120VAC, 1phase, 60Hz is not available, a variety of single phase control transformers can be provided as an option.
Blower Power: Blower power is typically provided by an outside source. Selected load banks are available with blower power derived from the power source under test.
Metering: A variety of analog and digital metering packages are available for various models for display of volts, amps, frequency, KW, KVAR, power factor, KVA, including data logging and acquisition software (consult the factory.)

Specifications are subject to change without notice.


Skid Mounted Resistive/Reactive Load Bank Model: LPS

LPS Load Bank
* LPS Sales Bulletin 
* LPS Drawing Sets
   
The Avtron LPS Load Bank System provides an economical and convenient means for high capacity resistive and reactive load testing of AC power systems. Many specifications and local codes demand that such testing be performed at less than unity power factor, typically 0.8 p.f. To achieve a 0.8 power factor, the LPS combines resistive load (KW) with reactive load (KVAR). This combination provides a true test of the actual generator or UPS nameplate rating (KVA) and simulates a "real world" load. The Avtron LPS System is integrated on a rugged structural skid with provisions for overhead, four point lifting.
Capacity Minimum Load
Step Resolution
Load Voltage Blower Voltage Size Weight
(lbs.)
2000KW; 1500KVAR or 1500KW; 1125KVAR 50KW; 37.5KVAR or 5KW; 3.75KVAR 480VAC; 3phase; 600VAC; 3phase 480VAC; 3phase; 575VAC; 3phase 255"L, 76"W, 109"H 13,000

^ Back to Top

Note: Other models with different KW/KVAR and Voltage ratings are available on special order. 
Control Power: Typical power required for control circuit operation is 120VAC, 1phase, 60 Hz. If 120VAC, 1phase, 60Hz is not available, a variety of single phase control transformers can be provided as an option.
Blower Power:
Blower power is typically provided by an outside source. Selected load banks are available with blower power derived from the power source under test.
Metering: A variety of analog and digital metering packages are available for various models for display of volts, amps, frequency, KW, KVAR, power factor, KVA, including data logging and acquisition software (consult the factory.)

Specifications are subject to change without notice.

Container Resistive/Reactive Load Bank Model: LCV

LCV Load Bank
* LCV Sales Bulletin 
* LCV Drawing Sets
* LCV Engineering Specifications
The Avtron LCV load bank is designed to provide high capacity resistive and reactive loading of AC power systems such as diesel generator sets, turbines, or Uninterruptible Power Supplies (UPS). Many specifications and local codes demand that such testing by performed at less than unity power factor, typically 0.8 p.f. lagging. To achieve a 0.8 power factor, the LCV combines resistive load (KW) with reactive load (KVAR). This combination provides a true test of the actual generator or UPS nameplate rating (KVA) and simulates a "real world" load.
Capacity Minimum Load
Step Resolution
Load Voltage Blower Voltage Size Weight
(lbs.)
3750KVA 25KW
18.75KVAR
480VAC; 3phase 460VAC; 3phase; 60Hz 239"L, 96"W, 108"H 28,600
5000KVA 32,700
6250KVA 36,300

^ Back to Top

Note: Other models with different KW/KVAR and Voltage ratings are available on special order. 
Control Power:
Typical power required for control circuit operation is 120VAC, 1phase, 60 Hz. If 120VAC, 1phase, 60Hz is not available, a variety of single phase control transformers can be provided as an option.
Blower Power: Blower power is typically provided by an outside source. Selected load banks are available with blower power derived from the power source under test.
Digital Metering: Avtron Advanced Digital Monitoring System (
* ADMS (TM)) is provided for display of Volts, Amps, Frequency, KW, KVAR, Power Factor, KVA. Includes Communicator EXT (TM) data-logging software.

ADMS (TM) is a trademark of Avtron LoadBank, Inc. Communicator EXT (TM) is a trademark of Electro Industries/Gauge Tech. Specifications are subject to change without notice.

Home | Contact | Site Map | Privacy Policy | Terms of Use
Load Banks | Industrial Resistors | News | Support | Sales RepsAbout Us

Copyright 2012 Avtron LoadBank, Inc. All rights reserved.

*These are Adobe PDF files. 
Questions on PDF? Visit FAQ's on PDF